Handhold CH4 & O2 gas detector |
|
|
No: DSCH4O2
Details: 2 in 1 gas detector, testing two gases of ch4 and o2.
Application places: portable CH4/O2 Warning detector can be applied to detect the concentration of CH4 gas and the 02 in the coal mine, tunnel and other continuous monitoring environment. When the gas concentration is exceeded, the detector can make sound, light, vibration alarm automatically. It can be portable used by relevant staff, managers, professionals, mobile workers. Also it can be used in the above-mentioned fixed places.
Technical indicator |
Parameter |
Measuring range |
( 0.00~4.00 ) %CH4; O2: £¨0~30.0£©%vol¡¢£¨0~100£©%vol |
Measurement error |
O2: ( 0.0~5.0 ) %vol: ±0.5%vol; ( > 5.0 ) %vol: full range ±3%
CH4: ( 0.00~1.00 ) %CH4£º±0.10% CH4
( 1.00~3.00 ) %CH4£º(true value)±0.10%
( 3.00~4.00 ) %CH4£º±0.30%CH4 |
Resolution ratio |
O2:? 0.1%vol; Ch4: 0.01%CH4 |
Display |
Liquid crystal display£¨LCD£©display |
Response time |
O2: ≤35s(T90); CH4: ≤20S ( T90 ) |
Alarm sound intensity |
≥75dB |
Alarm light |
≥20M visible |
Alarm point |
can be set ?in full proceed |
Alarm way |
Sound, light |
Continuous working time |
£¾3 months ( without backlight) |
Sensor lifetime |
≥2 year |
Working current |
< 1mA ( without backlight) |
Battery model |
PL123450 |
Charging time |
4-5 hours |
Protection degree |
IP54 |
|