home > Á¦Ç°¼Ò°³ > °¡½ºÃøÁ¤Àåºñ
Handhold CL2 gas detector

No: DSCL2
Details: detecting the cl2 gas
Application place: it’s widely used in chemical plant, water plant, metallurgy, textile, paper and other industries, the places which has liquid chlorine dangerous gas.


Technical indicator

Parameter

Measuring range

£¨0~20£©ppm

Measurement error

measured value±3%

Resolution ratio

0.01ppm

Display

Liquid crystal display£¨LCD£©display

Response time

≤20s(T90)

Alarm sound intensity

≥75dB

Alarm light

≥20M visible

Alarm point

can be set ?in full proceed

Alarm way

Sound, light

Continuous working time

£¾3 months ( without backlight)

Sensor lifetime

≥2 year

Working current

< 1mA ( without backlight)

Battery model

PL123450

Charging time

4-5 hours

Protection degree

IP54