home > Á¦Ç°¼Ò°³ > °¡½ºÃøÁ¤Àåºñ
Portable gas detection alarm for Methane

No:DS CH4
Details: CH4 gas detection
Application places: Underground Coal Mine, petrochemical, metallurgical, chemical, municipal gas, and other places at the scene detection;


Technical indicator

Parameter

Measuring range

( 0.00~4.00 ) %CH4

Measurement error

( 0.00~1.00 ) %CH4£º±0.10% CH4
( 1.00~3.00 ) %CH4£º(true value)±0.10%
( 3.00~4.00 ) %CH4£º±0.30%CH4

Resolution ratio

0.01%CH4

Display

Display digital diode£¨LED£©display

Response time

≤20S ( T90 )

Alarm sound intensity

≥75dB

Alarm light

≥20M visible

Alarm point

can be set ?in full proceed(factory setting1.00%CH 4)

Alarm way

Sound, light

Continuous working time

£¾10 hours

Sensor lifetime

≥1year

Working current

130mA

Battery model

PL123450

Charging time

4-5 hours

Protection degree

IP54